Elektriske stillingsindikatorer: Produktliste

Elektriske stillingsindikatorer: Produktliste

GEMÜ 1205
1205
  • Ambient temperature:-20 to 60 °C
  • Linear measuring range:2 to 70 mm
  • Supply voltages:250 V AC
  • Protection class:IP 65
  • Electrical connection type:M20 cable gland
  • Switch types:Microswitch
  • Conformities:ATEX
GEMÜ 1211
1211
  • Ambient temperature:-20 to 60 °C
  • Linear measuring range:2 to 70 mm
  • Protection class:IP 65
  • Electrical connection types:PG 13.5 cable gland
  • Switch types:2-wire proximity switch (NAMUR)
  • Communication modes:None
  • Conformities:ATEX
  • Supply voltages:8 V DC
GEMÜ 1214
1214
  • Ambient temperature:-20 to 60 °C
  • Linear measuring range:2 to 70 mm
  • Supply voltages:8 V DC
  • Protection class:IP 65
  • Electrical connection type:PG 13.5 cable gland | M12 plug
  • Switch types:2-wire proximity switch (NAMUR) | 3-wire proximity switch
  • Conformities:EAC
GEMÜ 1215
1215
  • Ambient temperature:-15 to 60 °C
  • Supply voltages:230 V AC, 50/60 Hz | 24 V DC
  • Protection class:IP 65
  • Electrical connection types:PG 11 cable gland | M12 plug
  • Switch types:Microswitch
  • Conformities:ATEX | EAC
GEMÜ 1230
1230
  • Ambient temperature:-20 to 60 °C
  • Linear measuring range:2 to 20 mm
  • Supply voltages:10 - 30 V DC | 250 V AC
  • Protection class:IP 65
  • Electrical connection type:M16 cable gland | M12 plug
  • Switch types:Microswitch
  • Conformities:CSA | EAC | UL Recognized
GEMÜ 1231
1231
  • Ambient temperature:-20 to 60 °C
  • Linear measuring range:2 to 20 mm
  • Supply voltages:8 V NAMUR
  • Protection class:IP 65
  • Electrical connection type:M16 cable gland | M12 plug
  • Switch types:2-wire proximity switch (NAMUR)
  • Conformities:ATEX | IECEx
GEMÜ 1232
1232
  • Ambient temperature:-20 to 60 °C
  • Linear measuring range:2 to 20 mm
  • Supply voltages:10 - 30 V DC | 8 V NAMUR
  • Protection class:IP 65
  • Electrical connection type:M16 cable gland | M12 plug
  • Switch types:2-wire proximity switch (NAMUR) | 3-wire proximity switch
  • Conformities:CSA | EAC | UL Recognized
GEMÜ 1234
1234
  • Ambient temperature:-10 to 70 °C
  • Linear measuring range:1 to 10 mm
  • Supply voltages:24 V DC
  • Electrical connection type:M12 plug
  • Protection class:IP 65
GEMÜ 1235
1235
  • Ambient temperature:-10 to 70 °C
  • Linear measuring range:2,0 to 74,4 mm
  • Supply voltages:24 V DC
  • Electrical connection types:
  • Communication modes:IO-Link | Without
  • Protection class:IP 67
  • Conformities:EAC | Functional safety | UL listed
GEMÜ 1240
1240
  • Ambient temperature:0 to 60 °C
  • Linear measuring range:5 to 75 mm
  • Supply voltages:24 V DC | 250 V AC | 8 V NAMUR
  • Protection class:IP 67
  • Electrical connection type:M16 cable gland | M12 plug
  • Switch types:Microswitch | 2-wire proximity switch (NAMUR) | 3-wire proximity switch
GEMÜ 1241
1241
  • Ambient temperature:0 to 60 °C
  • Linear measuring range:5 to 75 mm
  • Supply voltages:8 V NAMUR
  • Protection class:IP 67
  • Electrical connection type:M16 cable gland | M12 plug
  • Switch types:2-wire proximity switch (NAMUR)
  • Conformities:ATEX | IECEx
GEMÜ 1242
1242
  • Ambient temperature:0 to 60 °C
  • Linear measuring range:2 to 75 mm
  • Radial measuring range:0to 90°
  • Supply voltages:24 V DC
  • Protection class:IP 67
  • Electrical connection types:M12 plug
  • Communication modes:AS-Interface | DeviceNet | IO-Link
  • Conformities:ATEX | CSA | EAC | ETL Listed C US | IECEx | NEC 500
GEMÜ 4240
4240
  • Ambient temperature:0 to 60 °C
  • Linear measuring range:5 to 75 mm
  • Radial measuring range:0to 90°
  • Flow rate:250 Nl/min
  • Supply voltages:24 V DC | 250 V AC | 8 V DC
  • Protection class:IP 65, IP 67
  • Electrical connection types:Cable glands
  • Switch types:Microswitch | 2-wire proximity switch (NAMUR) | 3-wire proximity switch
GEMÜ 4241
4241
  • Measuring range: Max. 75 mm, linear | Max. 90°, radial
  • Ambient temperature: 0 to 50 °C
  • Flow rate: 250 Nl/min
  • Electrical connection types: M16 cable gland
  • Switch types: 2-wire proximity switch (NAMUR)
  • Communication modes:
  • Supply voltages: 8 V DC
  • Conformities: ATEX | EAC | IECEx
GEMÜ 4242
4242
  • Ambient temperature:0 to 60 °C
  • Linear measuring range:2 to 75 mm
  • Flow rate:14 Nl/min | 23 Nl/min | 250 Nl/min
  • Supply voltage:24 V DC
  • Mode of action:Double acting | Single acting
  • Communication modes:AS-Interface | DeviceNet | IO-Link
  • Electrical connection types:M12 plug
  • Protection class:IP 65, IP 67
  • Conformities:ATEX | EAC | ETL Listed C US | Functional safety | IECEx
GEMÜ C12A
C12A
  • Ambient temperature:-10 to 55 °C
  • Linear measuring range:3 to 6 mm
  • Supply voltages:5 - 24 V DC ± 10 %
  • Electrical connection type:open cable ends
  • Protection class:IP 64
GEMÜ LSC
LSC
  • Ambient temperature:-25 to 80 °C
  • Radial measuring range:0 - 90°
  • Supply voltages:5–250 V AC/DC
  • Protection class:IP66, IP67
  • Electrical connection types:Plug, Harting | Plug, Hirschmann | M20 cable gland | M12 plug | NPT threaded connection
  • Switch types:2-wire proximity switch (NAMUR) | Reed contact | Microswitch | 3-wire proximity switch
  • Conformities:ATEX | EAC | Functional safety | IECEx
GEMÜ LSF
LSF
  • Ambient temperature:-25 to 85 °C
  • Radial measuring range:0to 90°
  • Supply voltages:10 - 30 V DC | 8 V NAMUR
  • Protection class:IP 67
  • Electrical connection types:M12 plug
  • Switch types:2-wire proximity switch (NAMUR) | 3-wire proximity switch
  • Conformities:ATEX | CSA | Functional safety | IECEx | UL Recognized

Komplet afsaltning af kedelfødevand vha. ionbyttere

Komplet afsaltning af kedelfødevand vha. ionbyttere
I dampkedelanlæg fører de salte, der er opløst i vandet, til korrosion og aflejringer. For at forhindre dette stilles der vigtige krav til kedelfødevandets kvalitet afhængigt af dampkedlens driftsform og konstruktion. I et anlæg til komplet afsaltning fjernes de salte,
mere