Control module
Filter
00: OPEN/CLOSE control, relay not reversible
0E: OPEN/CLOSE control, 2 additional potential-free limit switches, relay not reversible
0P: OPEN/CLOSE control, potentiometer output, relay not reversible
A0: OPEN/CLOSE control
A31: ON/OFF actuator, 3-position actuator, additional potential-free limit switches, Failsafe battery pack (NC), preferred direction adjustable
A3: ON/OFF actuator, 3-position actuator, additional potential-free limit switches
AB1: OPEN/CLOSE control, 2 additional potential-free limit switches, additionally a potential-free error output for current limitation (max. torque exceeded), thermal limitation and program error, failsafe battery pack (NC), preferred direction adjustable
AB2: OPEN/CLOSE control, 2 additional potential-free limit switches, additionally a potential-free error output for current limitation (max. torque exceeded), thermal limitation and program error, failsafe battery pack (NO), preferred direction adjustable
AB: OPEN/CLOSE control, 2 additional potential-free limit switches, 2 additional potential-free torque switches, class A (EN15714-2)
ADP: OPEN/CLOSE control, positioner AUMATIC (AC 01.2), fieldbus interface Profibus DP-V0, basic AUMA NORM (S2 15 minutes, class A/B actuator), TPC AA000-1A1-A000, TPA xxR100-0I1-000
AE1: OPEN/CLOSE control, 2 additional potential-free limit switches, BSR battery pack (NC)
AE2: OPEN/CLOSE control, 2 additional potential-free limit switches, BSR battery pack (NO)
AE: OPEN/CLOSE control, 2 additional potential-free limit switches, Class A (EN15714-2)
AMB: OPEN/CLOSE control, positioner AUMATIC (AC 01.2), Modbus RTU fieldbus interface, basic AUMA NORM (S2 15 minutes, class A/B actuator), TPC AC000-1A1-A000, TPA xxR100-0I1-000
AMI: OPEN/CLOSE control, positioner AUMATIC (AC 01.2), Modbus TCP/IP fieldbus interface, basic AUMA NORM (S2 15 minutes, class A/B actuator), TPC AC000-1A1-A5E0, TPA xxR100-0I1-000
AP1: OPEN/CLOSE control, 2 additional potential-free limit switches, potentiometer output 5 kOhm, Failsafe battery pack (NC), preferred direction adjustable
APN: ON/OFF actuator, AUMATIC positioner (AC 01.2), fieldbus interface ProfiNet, basic AUMA NORM SQ (S2 15 minutes, actuator class A/B), TPC AN000N1A2-A000, TPA xxR100-0I1-000
AP: OPEN/CLOSE control, potentiometer output, class A (EN15714-2)
AR: OPEN/CLOSE actuator without control, external wiring necessary, 2 additional potential-free limit switches, analog position feedback 21.4 EWG (0/4-20mA), AUMA NORM (S2 15 minutes actuator class A/B), TPAxxR1AA-1E1-000
ASC: OPEN/CLOSE control, positioner AUMATIC (AC 01.2), basic AUMA NORM (S2 15 minutes, class A/B actuator), TPC A-1B1-1C1-A000, TPA xxR100-0I1-000
ASM: OPEN/CLOSE actuator, remote and local control, AUMA MATIC (AM 01.1), basic AUMA NORM (S2 15 minutes, actuator class A/B), MSP 1110KC3-F18E1, TPA xxR1AA-101-000
E0: Control module without control, external wiring necessary, basic AUMA NORM SQR/SAR (S4 ED 25%, actuator class C), only at 400V 50Hz and 230V 50/60Hz, TPAxxR1AA-101-000
E11: Positioner DPS, external set value 0-10V, BSR battery pack (NC)
E12: Positioner DPS, external set value 0-10V, BSR battery pack (NO)
E1: Control module, external set value 0-10 VDC
E21: Positioner, external set value 4-20mA, battery pack (NC)
E22: Positioner, external set value 4-20mA, battery pack (NO)
E2: Control module, external set value 0/4-20mA
EB1: POSI positioner, 2 additional potential-free limit switches, control and feedback signal, adjustable to 0-20mA/4-20mA/0-10V, failsafe battery pack (NC), preferred direction adjustable
EB2: POSI positioner, 2 additional potential-free limit switches, control and feedback signal, adjustable to 0-20mA/4-20mA/0-10V, failsafe battery pack (NO), preferred direction adjustable
EB: Control module without control, external wiring necessary, 2 additional potential-free limit switches, additional potential-free torque switches
EDP: Control module, positioner AUMATIC (AC 01.2), Profibus DP fieldbus interface, basic AUMA NORM SQR/SAR (S4 ED 25%, actuator class C), only at 400V 50Hz and 230V 50/60Hz, TPC AA000-1A1-A000, TPA xxR100-0I1-000 For actuator type PF, TPCPA0B1AxA100000 ProfiBus, without AC01.2
EMB: Control module, remote and local control, AUMATIC (AC 01.2), Fieldbus interface Modbus RTU, basic AUMA NORM SQR/SAR (S4 ED 25% actuator class C), only at 400V 50Hz and 230V 50Hz/60Hz, TPC AC000-1A1-A000, TPA xxR100-0I1-000 For actuator type PF, TPCPC0B1AxA100000 ModBus RTU, without AC01.2
EMI: Control module, remote and local control, AUMATIC (AC 01.2), Fieldbus interface Modbus TCP/IP, basic AUMA NORM SQR/SAR (S4 ED 25% actuator class C), only at 400V 50Hz and 230V 50Hz/60Hz, TPC AC000-1A1-A5E0, TPA xxR100-0I1-000
EPN: Control actuator, remote and on-site control, AUMATIC (AC 01.2), fieldbus interface ProfiNet, basic AUMA NORM SQR (S4 25% duty, actuator class C), only for 400V 50Hz and 230V 50Hz/60Hz, TPC AN000N1A2-A000, TPA xxR100-0I1-000
ER: Control module without control, external wiring necessary, 2 additional potential-free limit switches, analog position feedback EWG, external set value 0/4-20mA, basic AUMA NORM SQR/SAR (S4 ED 25% actuator class C), only at 400V 50Hz and 230V 50Hz/60Hz, TPAxxR1AA-1E1-000
ESC: Control module, positioner AUMATIC (AC 01.2), basic AUMA NORM SQR/SAR (S4 ED 25% actuator class C), only at 400V 50Hz and 230V 50Hz/60Hz, TPC A-1B1-1C1-A000, TPA xxR100-0I1-000
ESP: Control module, positioner POSIGAM, remote and on-site control, programmable outputs, basic BERNARD SQ/ST (S4 50% duty, 1200 starts/hour, actuator class C)
Actuator version
Filter
2015: Actuator, motorized, operating time 11s, torque 15Nm, GEMUE, size 2 supply voltage B4, C4
2070: Actuator, motorized, operating time 15s, torque 70Nm, GEMUE, size 2 supply voltage C1
3006: Actuator, motorized, operating time 4s, torque 6Nm, GEMÜ, size 3, supply voltage B1, C1, B4, C4
3015: Actuator, motorized, operating time 11s, torque 15Nm, GEMUE, size 3 supply voltage B1, C1
3035: Actuator, motorized, operating time 15s, torque 35Nm, GEMUE, size 3 supply voltage C1
3055: Actuator, motorized, operating time 15s, torque 55Nm, GEMUE, size 3 supply voltage C1
4100: Actuator, motorized, operating time 20s, torque 100Nm, GEMUE, size 4 supply voltage C1
4200: Actuator, motorized, operating time 16s, torque 200Nm, GEMUE, size 4 supply voltage C1
AQ05H: Actuator, motorized, operating time 16s, torque 150Nm, AUMA, type SQ class A (EN15714-2), OPEN/CLOSE control, 75° to 105°, continuously adjustable, flasher unit for travel indication, heating, mechanical position indicator, KS, layer thickness 0.140mm, RAL7037, manual override, IP68
AQ05L: Actuator, motorized, operating time 32s, torque 150Nm, AUMA, type SQ class A (EN15714-2), OPEN/CLOSE control, 75° to 105°, continuously adjustable, flasher unit for travel indication, heating, mechanical position indicator, KS, layer thickness 0.140mm, RAL7037, manual override, IP68
AQ07H: Actuator, motorized, operating time 16s, torque 300Nm, AUMA, type SQ class A (EN15714-2), OPEN/CLOSE control, 75° to 105°, continuously adjustable, flasher unit for travel indication, heating, mechanical position indicator, KS, layer thickness 0.140mm, RAL7037, manual override, IP68
AQ07L: Actuator, motorized, operating time 32s, torque 300Nm, AUMA, type SQ class A (EN15714-2), OPEN/CLOSE control, 75° to 105°, continuously adjustable, flasher unit for travel indication, heating, mechanical position indicator, KS, layer thickness 0.140mm, RAL7037, manual override, IP68
AQ10L: Actuator, motorized, operating time 32s, torque 600Nm, AUMA, type SQ class A (EN15714-2), OPEN/CLOSE control, 75° to 105°, continuously adjustable, flasher unit for travel indication, heating, mechanical position indicator, KS, layer thickness 0.140mm, RAL7037, manual override, IP68
AQ12L: Actuator, motorized, operating time 32s, torque 1200Nm, AUMA, type SQ class A (EN15714-2), OPEN/CLOSE control, 75° to 105°, continuously adjustable, flasher unit for travel indication, heating, mechanical position indicator, KS, layer thickness 0.140mm, RAL7037, manual override, IP68
AQ14O: Actuator, motorized, operating time 48s, torque 2400Nm, AUMA, type SQ class A (EN15714-2), OPEN/CLOSE control, 75° to 105°, continuously adjustable, flasher unit for travel indication, heating, mechanical position indicator, KS, layer thickness 0.140mm, RAL7037, manual override, IP68
J4C14: Actuator, motorized, operating time 34 s, torque 140 Nm, J+J, type J4, heating, IP67
J4C20: Actuator, motorized, operating time 9s, torque 20Nm, J+J, type J4 heating, IP67
J4C30: Actuator, motorized, operating time 58 s, torque 300 Nm, J+J, type J4, heating, IP67
J4C35: Actuator, motorized, operating time 9s, torque 35Nm, J+J, type J4 heating, IP67
J4C55: Actuator, motorized, operating time 13 s, torque 55 Nm, J+J, type J4, heating, IP67
J4C85: Actuator, motorized, operating time 29 s, torque 85 Nm, J+J, type J4, heating, IP67
PF08A: Actuator, motorized, operating time 4s, torque 80Nm, AUMA Profox PF-Q
PF08D: Actuator, motorized, operating time 8s, torque 80Nm, AUMA Profox PF-Q
PF08H: Actuator, motorized, operating time 16s, torque 80Nm, AUMA Profox PF-Q
PF15D: Actuator, motorized, operating time 8s, torque 150Nm, AUMA Profox PF-Q
PF15H: Actuator, motorized, operating time 16s, torque 150Nm, AUMA Profox PF-Q
PF15L: Actuator, motorized, operating time 32s, torque 150Nm, AUMA Profox PF-Q
PF30I: Actuator, motorized, operating time 22s, torque 300Nm, AUMA Profox PF-Q
PF30N: Actuator, motorized, operating time 45s, torque 300Nm, AUMA Profox PF-Q
PF30P: Actuator, motorized, operating time 63s, torque 300Nm, AUMA Profox PF-Q
PF60N: Actuator, motorized, operating time 45s, torque 600Nm, AUMA Profox PF-Q
PF60S: Actuator, motorized, operating time 75s, torque 600Nm, AUMA Profox PF-Q
RP100: AUMA RP actuator With removable hand crank, insulation class B mechanical position indicator, heating protection class IP67 acc. to EN 60529, C2 acc. to EN ISO 12944-2, standard ambient temperature -20 °C to +60 °C torque measurement and torque limits,
RP32: AUMA RP actuator With removable hand crank, insulation class B mechanical position indicator, heating protection class IP67 acc. to EN 60529, C2 acc. to EN ISO 12944-2, standard ambient temperature -20 °C to +60 °C torque measurement and torque limits,
RP64: AUMA RP actuator With removable hand crank, insulation class B mechanical position indicator, heating protection class IP67 acc. to EN 60529, C2 acc. to EN ISO 12944-2, standard ambient temperature -20 °C to +60 °C torque measurement and torque limits,
VR25: Actuator, motorized, operating time 7s, torque 25Nm, BAR/VALPES, V-series 24V AC/DC
VR45: Actuator, motorized, operating time 15s, torque 45Nm, BAR/VALPES, V-series
VR75: Actuator, motorized, operating time 20s, torque 75Nm, BAR/VALPES, V-series