Type
Filter
653: Diaphragm valve, manually operated, plastic handwheel, stainless steel distance piece electropolished, optical position indicator
DN
Filter
4: DN 4
6: DN 6
8: DN 8
10: DN 10
15: DN 15
20: DN 20
25: DN 25
32: DN 32
40: DN 40
50: DN 50
65: DN 65
80: DN 80
100: DN 100
Body configuration
Filter
D: 2/2-way body
Connection type
Filter
0: Spigot DIN
8: Flanges EN 1092 / PN16 / form B, Face to face EN 558, series 1, ISO 5752, basic series 1
16: Spigot DIN EN 10357 series B (edition 2014; formerly DIN 11850 series 1)
17: Spigot EN 10357, series A / DIN 11866, series A formerly DIN 11850, series 2
18: Spigot DIN 11850 series 3
32: Spigot JIS-G 3459 Schedule 5s
34: Flange JIS B2220, 10K, RF, face-to-face dimension FTF EN 558, series 1, ISO 5752, basic series 1, length only for body configuration D
35: Spigot JIS-G 3447
36: Spigot JIS-G 3459 Schedule 10s
37: Spigot SMS 3008
38: Flanges ANSI Class 150 RF, Face to face MSS SP-88
39: Flanges ANSI Class 125/150 RF, Face to face EN 558, series 1, ISO 5752, basic series 1
55: Spigot BS 4825, part 1
59: Spigot ASME BPE / DIN EN 10357 series C (from edition 2022) / DIN 11866 series C
60: Spigot ISO 1127 / DIN EN 10357 series C (edition 2014) / DIN 11866 series B
63: Spigot ANSI/ASME B36.19M Schedule 10s
64: Spigots ANSI/ASME B36.19M Schedule 5s
65: Spigot ANSI/ASME B36.19M Schedule 40s
80: Clamps ASME BPE Face to face ASME BPE
81: Clamp DIN 32676 for pipe ISO 1127 / DIN EN 10357 series C (edition 2014), DN 6 - DN 10, clamp OD 50.5 mm
82: Clamps DIN 32676 series B Face to face EN 558, series 7
84: Clamps for tube BS 4825 part 1 DN 15 and 20, clamp OD 25.0 mm length EN 558 series 7
86: Clamp DIN 32676 series A
87: Clamp ISO 2852 / SMS 3017
88: Clamp ASME BPE, for pipe ASME BPE, face-to-face dimension FTF EN 558, series 7, length only for body configuration D
8A: Clamps DIN 32676 series A Face to face EN 558, series 7
8E: Clamp ISO 2852 for pipe ISO 2037, clamp SMS 3017 for pipe SMS 3008 face-to-face dimension FTF EN 558 series 7, length only for body configuration D
8F: Clamp IDF/ISO, for pipe JIS-G 3447, face-to-face dimension FTF EN 558, series 7, length only for body configuration D
8H: Clamp IDF/ISO, for pipe JIS-G 3459, face-to-face dimension FTF EN 558, series 7, length only for body configuration D
8P: Clamp DIN 32676 series C, face-to-face dimension FTF ASME BPE, dimension only for body configuration D
8T: Clamp DIN 32676 series C, face-to-face dimension FTF EN 558 series 7, dimension only for body configuration D
A1: Aseptic flange DIN 11864-NF, for pipe DIN 11866, series A and EN 10357, series A, face-to-face dimension FTF EN 558, series 1, length only for body configuration D
A2: Aseptic flange DIN 11864-BF, for pipe DIN 11866, series A and EN 10357, series A, face-to-face dimension FTF EN 558, series 1, length only for body configuration D
A4: Aseptic flange DIN 11864-NF, for pipe DIN 11866, series B and EN ISO 1127, face-to-face dimension FTF EN 558, series 1, length only for body configuration D
A5: Aseptic flange DIN 11864-BF, for pipe DIN 11866, series B and EN ISO 1127, face-to-face dimension FTF EN 558, series 1, length only for body configuration D
A7: Aseptic flange DIN 11864-NF, for pipe DIN 11866, series C and ASME BPE, face-to-face dimension FTF EN 558, series 1, length only for body configuration D
A8: Aseptic flange DIN 11864-BF, for pipe DIN 11866, series C and ASME BPE, face-to-face dimension FTF EN 558, series 1, length only for body configuration D
C1: Aseptic union DIN 11864-GS, for pipe DIN 11866, series A and EN 10357, series A
C2: Aseptic union DIN 11864-BS, for pipe DIN 11866, series A and EN 10357, series A
C4: Aseptic union DIN 11864-GS, for pipe DIN 11866, series B and EN ISO 1127
C5: Aseptic union DIN 11864-BS, for pipe DIN 11866, series B and EN ISO 1127
C7: Aseptic pipe union DIN 11864-GS, for pipe DIN 11866, series C and ASME BPE
C8: Aseptic union, DIN 11864-BS, for pipe, DIN 11866 series C and ASME BPE
E1: Aseptic clamp DIN 11864-NKS, for pipe DIN 11866, series A and EN 10357, series A face-to-face dimension FTF EN 558, series 7, length only for body configuration D
E2: Aseptic clamp DIN 11864-BKS, for pipe DIN 11866, series A and EN 10357, series A face-to-face dimension FTF EN 558, series 7, length only for body configuration D
E4: Aseptic clamp DIN 11864-NKS, for pipe DIN 11866, series B and EN ISO 1127, face-to-face dimension FTF EN 558, series 7, length only for body configuration D
E5: Aseptic clamp DIN 11864-BKS, for pipe DIN 11866, series B and EN ISO 1127, face-to-face dimension FTF EN 558, series 7, length only for body configuration D
E7: Aseptic clamp DIN 11864-NKS, for pipe DIN 11866, series C / ASME BPE, face-to-face dimension FTF EN 558, series 7, length only for body configuration D
E8: Aseptic clamp, DIN 11864-BKS, for pipe DIN 11866, series C / ASME BPE, face-to-face dimension FTF EN 558, series 7, length only for body configuration D
FV: Pipe union with front-flush stainless steel seal contour, union nut with internal thread (female)
MV: Pipe union with front-flush stainless steel seal contour, union nut with external thread (male)
U9: Spigots ASME BPE, spigot length 7mm
Valve body material
Filter
17: EN-GJS-400-18-LT (GGG-40.3), PFA lined
39: 1.4408, PFA lined
40: 1.4435 (F316L), forged body
41: 1.4435 (316L), block material
42: 1.4435 (BN2), forged body Δ Fe < 0.5 %
43: 1.4435 (BN2), block material, Δ Fe < 0.5%
44: 1.4539 / UNS N08904, block material
C3: 1.4435, investment casting
E3: 1.4529, UNS N08367, block material Alloy
F4: 1.4539, forged body
Diaphragm material
Filter
2: NBR
4: FKM
13: EPDM
17: EPDM
19: EPDM
29: EPDM
54: PTFE/EPDM one-piece
56: PTFE/FKM
71: PTFE/PVDF/EPDM three-piece
3A: EPDM
5M: PTFE/EPDM two-piece
Control function
Filter
0: Manually operated
Actuator version
Filter
0TH: With seal adjuster and stroke limiter
0XA: With seal adjuster and stroke limiter, mounting for proximity switches M8 x 1
0XB: With seal adjuster and stroke limiter, locking device (both directions), mounting for proximity switches M 8x1
0XF: With seal adjuster and stroke limiter, locking device to prevent closing, mounting for proximity switches M 8x1
0XK: With seal adjuster and stroke limiter, locking device to prevent opening, mounting for proximity switches M 8x1
1TH: With seal adjuster and stroke limiter
1TN: Without seal adjuster and stroke limiter
1XA: With seal adjuster and stroke limiter, mounting for proximity switches M 8x1
1XB: With seal adjuster and stroke limiter, locking device (both directions), mounting for proximity switches M 8x1
1XF: With seal adjuster and stroke limiter, locking device to prevent closing, mounting for proximity switches M 8x1
1XK: With seal adjuster and stroke limiter, locking device to prevent opening, mounting for proximity switches M 8x1
1YB: Without seal adjuster and stroke limiter , locking device (both directions), mounting for proximity switches M 8x1
2TH: With seal adjuster and stroke limiter
2TN: Without seal adjuster and stroke limiter
2XA: With seal adjuster and stroke limiter, mounting for proximity switches M 8x1
2XB: With seal adjuster and stroke limiter, locking device (both directions), mounting for proximity switches M 8x1
2XF: With seal adjuster and stroke limiter, locking device to prevent closing, mounting for proximity switches M 8x1
2XK: With seal adjuster and stroke limiter, locking device to prevent opening, mounting for proximity switches M 8x1
3TH: With seal adjuster and stroke limiter
3TN: Without seal adjuster and stroke limiter
3XA: With seal adjuster and stroke limiter, mounting for proximity switches M 8x1
3XB: With seal adjuster and stroke limiter, locking device (both directions), mounting for proximity switches M 8x1
3XF: With seal adjuster and stroke limiter, locking device to prevent closing, mounting for proximity switches M 8x1
3XK: With seal adjuster and stroke limiter, locking device to prevent opening, mounting for proximity switches M 8x1
3YB: Without seal adjuster and stroke limiter , locking device (both directions), mounting for proximity switches M 8x1
4DH: Operator size 4DH, for 2/2-way body, with seal adjuster and stroke limiter
4DN: Operator size 4DN, for 2/2-way body
4TH: With seal adjuster and stroke limiter
4TN: Without seal adjuster and stroke limiter
4XA: With seal adjuster and stroke limiter, mounting for proximity switches M 8x1
4XB: With seal adjuster and stroke limiter, locking device (both directions), mounting for proximity switches M 8x1
4XE: Operator size 4XE, with gland packing
4XF: With seal adjuster and stroke limiter, locking device to prevent closing, mounting for proximity switches M 8x1
4XK: With seal adjuster and stroke limiter, locking device to prevent opening, mounting for proximity switches M 8x1
4YB: Without seal adjuster and stroke limiter , locking device (both directions), mounting for proximity switches M 8x1
4YK: Without seal adjuster and stroke limiter , locking device to prevent opening, mounting for proximity switches M 8x1
5TN: Without seal adjuster and stroke limiter
5TS: With seal adjuster
5XA: With seal adjuster, mounting for proximity switches M 12x1
5XB: with seal adjuster, locking device (both directions), for mounting of proximity switches M12 x 1
5XK: with seal adjuster, locking device to prevent opening, for mounting of proximity switches M12 x 1
5YB: Without seal adjuster, locking device (both directions), mounting for proximity switches M 12x1
6TN: Without seal adjuster and stroke limiter
6TS: With seal adjuster
6XA: With seal adjuster, mounting for proximity switches M 12x1
6XB: with seal adjuster, locking device (both directions), for mounting of proximity switches M12 x 1
6XK: with seal adjuster, locking device to prevent opening, for mounting of proximity switches M12 x 1
DN
-2
Filter
OHNE
6: DN 6
8: DN 8
10: DN 10
15: DN 15
20: DN 20
25: DN 25
32: DN 32
40: DN 40
50: DN 50
65: DN 65
80: DN 80
100: DN 100
125: DN 125
150: DN 150
Connection type, spigot 2
Filter
OHNE
0: Spigot DIN
16: Spigot DIN EN 10357 series B (edition 2014; formerly DIN 11850 series 1)
17: Spigot EN 10357, series A / DIN 11866, series A formerly DIN 11850, series 2
18: Spigot DIN 11850 series 3
35: Spigot JIS-G 3447
36: Spigot JIS-G 3459 Schedule 10s
37: Spigot SMS 3008
55: Spigot BS 4825, part 1
59: Spigot ASME BPE / DIN EN 10357 series C (from edition 2022) / DIN 11866 series C
60: Spigot ISO 1127 / DIN EN 10357 series C (edition 2014) / DIN 11866 series B
64: Spigots ANSI/ASME B36.19M Schedule 5s
80: Clamp ASME BPE
81: Clamp DIN 32676 for pipe ISO 1127 / DIN EN 10357 series C (edition 2014), DN 6 - DN 10, clamp OD 50.5 mm
82: Clamps DIN 32676 series B, for pipe EN ISO 1127
86: Clamp DIN 32676 series A
87: Clamp ISO 2852 for pipe ISO 2037, clamp SMS 3017 for pipe SMS 3008
88: Clamp ASME BPE, for pipe ASME BPE
8A: Clamp DIN 32676 series A
8P: Clamp DIN 32676 series C
8T: Clamp DIN 32676 series C
A1: Aseptic flange DIN 11864-NF, for pipe DIN 11866, series A and EN ISO 10357, series A
A2: Aseptic flange DIN 11864-BF, for pipe DIN 11866, series A and EN ISO 10357, series A
A4: Aseptic flange DIN 11864-NF, for pipe DIN 11866, series B and EN ISO 1127
A5: Aseptic flange DIN 11864-BF, for pipe DIN 11866, series B and EN ISO 1127
A7: Aseptic flange DIN 11864-NF, for pipe DIN 11866, series C and ASME BPE, face-to-face dimension FTF EN 558, series 1, length only for body configuration D
A8: Aseptic flange DIN 11864-BF, for pipe DIN 11866, series C and ASME BPE
C1: Aseptic union DIN 11864-GS, for pipe DIN 11866, series A and EN 10357, series A
C2: Aseptic union DIN 11864-BS, for pipe DIN 11866, series A and EN 10357, series A
C4: Aseptic union DIN 11864-GS, for pipe DIN 11866, series B and EN ISO 1127
C5: Aseptic union DIN 11864-BS, for pipe DIN 11866, series B and EN ISO 1127
C7: Aseptic pipe union DIN 11864-GS, for pipe DIN 11866, series C and ASME BPE
C8: Aseptic union, DIN 11864-BS, for pipe, DIN 11866 series C and ASME BPE
E1: Aseptic clamp DIN 11864-NKS, for pipe DIN 11866, series A and EN 10357, series A
E2: Aseptic clamp DIN 11864-BKS, for pipe DIN 11866, series A and EN 10357, series A
E4: Aseptic clamp, DIN 11864-NKS, for pipe, DIN 11866 series B and EN ISO 1127
E5: Aseptic clamp, DIN 11864-BKS, for pipe, DIN 11866 series B and EN ISO 1127
E7: Aseptic clamp DIN 11864-NKS, for pipe DIN 11866, series C / ASME BPE
E8: Aseptic clamp DIN 11864-BKS, for pipe DIN 11866, series C / ASME BPE
FV: Pipe union with front-flush stainless steel seal contour, union nut with internal thread (female)
U9: Spigots ASME BPE, spigot length 7mm
Execution type
Filter
OHNE
1500: Ra <= 6.3 µm (250 µin.) for media wetted surfaces, blasted internal / external
1502: Ra <= 0.8 µm (30 µin.) for media wetted surfaces, according DIN 11866 H3, mechanically polished internal
1503: Ra <= 0.8 µm (30 µin.) media wetted surfaces, to DIN 11866 HE3, electropolished internal / external
1507: Ra ≤ 0.6 µm (25 µin.) for media wetted surfaces, mechanically polished internal
1508: Ra ≤ 0.6 μm (25 μin.) for media wetted surfaces, electropolished internal/external
1516: Ra ≤ 0.25 μm (10 μin.) for media wetted surfaces *), to DIN 11866 HE5, electropolished internal / external, *) for pipe inside-Ø < 6 mm, in the spigot Ra ≤ 0.38 µm
1527: Ra ≤ 0.25 μm (10 μin.) for media wetted surfaces *), to DIN 11866 H5, mechanically polished internal, *) for pipe inside-Ø < 6 mm, in the spigot Ra ≤ 0.38 µm
1536: Ra ≤ 0.4 µm (15 µin.) for media wetted surfaces, to DIN 11866 H4, mechanically polished internal
1537: Ra ≤ 0.4 µm (15 µin.) for media wetted surfaces, to DIN 11866 HE4, electropolished internal / external
1787: no surface roughness for complete part, used component: Ra ≤ 0.25 µm (9.8 µin.) for media wetted surfaces, no reworking of weld seams, used components electropolished internal/external
1799: no surface roughness for complete part, used component: Ra ≤ 0.4 µm (15 µin.) for media wetted surfaces, no reworking of weld seams, used components electropolished internal/external
1830: Media wetted area cleaned to ensure suitability for paint applications, parts sealed in plastic bag and surface 1508
1841: Media wetted parts cleaned for high purity media and packed in plastic bag and surface 1508
1850: Media wetted area cleaned to ensure suitability for paint applications, parts sealed in plastic bag and surface 1536
1874: Ra ≤ 0.6 µm (25 µin.) for media wetted surfaces, to ASME BPE SF6, Ra ≤ 1.2 µm (50 µin.) external, electropolished internal / external
1906: Ra ≤ 0.4 µm (15 µin.) for media wetted surfaces *), in accordance with DIN 11866 H4, Ra ≤ 0.8 µm (30 µin.) external, electropolished internal / external, *) for pipe inside-Ø ≤ 6 mm, in the spigot Ra ≤ 0.8 µm
1967: Ra max. 0.38 µm (15 µin.) for media wetted surfaces, in accordance with ASME BPE SF4, Ra ≤ 1.2 µm (50 µin.) external, electropolished internal/external
SF1: Ra Max. 0.51 μm (20 μin.) for media wetted surfaces, to ASME BPE SF1, mechanically polished internal
SF2: Ra Max. 0.64 μm (25 μin.) for media wetted surfaces, to ASME BPE SF2, mechanically polished internal
SF3: Ra Max. 0.76 μm (30 μin.) for media wetted surfaces, to ASME BPE SF3, mechanically polished internal
SF4: Ra Max. 0.38 µm (15 µin.) for media wetted surfaces, to ASME BPE SF4, electropolished internal / external
SF5: Ra Max. 0.51 µm (20 µin.) for media wetted surfaces, to ASME BPE SF5, electropolished internal / external
SF6: Ra Max. 0.64 μm (25 μin.) for media wetted surfaces, to ASME BPE SF6, electropolished internal / external
Special version
Filter
OHNE
H: Special version for higher operating pressures
CONEXO
Filter
OHNE
C: Integrated RFID chip for electronic identification and traceability