When welding is no option

Solution paper | PUPSIT with stainless steel valves

Limited installation space, additional connections and the effort of conventional welded solutions make it difficult to implement PUPSIT in existing plants. This solution paper shows how we developed a compact, weld-free multi-way stainless steel valve block tailored precisely to the process.

Integrate PUPSIT safely into your process

The foundation of your process safety

PUPSIT refers to the integrity test of a sterilized filter after sterilization, installation and handling, but before first product contact, to ensure its function and sterile barrier effect. Since the revision of EU GMP Annex 1, PUPSIT has been a concrete technical requirement for existing and new pharmaceutical plants.

In stainless steel plants in particular, installation space, additional connections, welding work, dead space and qualification effort are key challenges. We develop individually tailored product solutions that integrate process-relevant valves, connections and sensors. This allows PUPSIT to be implemented in a way that fits the plant, with reduced installation effort.

Our solution for your plant

Free solution paper

Discover in practical, real-world terms how we integrated PUPSIT into an existing stainless steel plant. Find out where conventional solutions reach their limits, what advantages our individually designed multi-way valve block offers and how to tell whether it's the right fit for your plant.

When welding isn't an option

What to expect:

  • 10 pages of practical expert knowledge on PUPSIT integration
  • An anonymized case study from an existing stainless steel plant
  • Concrete figures on installation space, dead space, weld seams and qualification effort
  • Decision guide: does a multi-way valve block fit your plant?
  • Technical guidance for your next PUPSIT solution