The GEMÜ 840 flowmeter operates according to the part flow principle The device consists of three parts: Main flow unit, part flow unit and manual diaphragm valve.
Good level of accuracy, simple operation
Impact resistant, corrosion resistant
Large measuring range 3 - 50 m³/h (depending on orifice diameter)
Part flow metering tube can also be easily replaced without downtime
The GEMÜ 840 flowmeter operates according to the part flow principle The device consists of three parts: Main flow unit, part flow unit and manual diaphragm valve.
Type: 846: Variable area flowmeter, part flow principle, PP float with magnet
RoHS conformance: R: Conformance to RoHS
DN: 65: DN 65
Body configuration: D: Straight through tube
Connection type: 0: Spigots DIN
Metering tube material: 5: PP, reinforced
O-ring material: 14: EPDM
Measuring range: 50000: Maximum measuring range of flowmeter
Medium: Wasser: Water
Temperature: 20°C: Medium temperature
Scale minimum: 6: Lower measuring range limit of scale
Scale maximum: 50: Upper measng range limit of scale
Unit: m³/h: Cubic metres per hour
Orifice material: 5: PP, reinforced
Orifice diameter: 52: Diameter 52 mm
The GEMÜ 840 flowmeter operates according to the part flow principle The device consists of three parts: Main flow unit, part flow unit and manual diaphragm valve.
Type: 846: Variable area flowmeter, part flow principle, PP float with magnet
RoHS conformance: R: Conformance to RoHS
DN: 65: DN 65
Body configuration: D: Straight through tube
Connection type: 0: Spigots DIN
Metering tube material: 5: PP, reinforced
O-ring material: 14: EPDM
Measuring range: 50000: Maximum measuring range of flowmeter
Medium: Wasser: Water
Temperature: 20°C: Medium temperature
Scale minimum: 6: Lower measuring range limit of scale
Scale maximum: 50: Upper measng range limit of scale
Unit: m³/h: Cubic metres per hour
Orifice material: 5: PP, reinforced
Orifice diameter: 52: Diameter 52 mm
Item number: 88049761 846R65D 0 514 55250000
The tender texts have been copied to the clipboard